Visual indicator glowing yellow – Smoke Sensor communicates with the main controller through the other modules.
Visual indicator pulsing yellow – Smoke Sensor tries to establish a routed communication with the main controller through other modules (repeaters). Visual indicator glowing green – Smoke Sensor communicates with the main controller directly. If a direct communication attempt fails, the device will try to establish a routed communication, through other modules, which will be signalled by visual indicator pulsing yellow. Visual indicator pulsing green – Smoke Sensor attempts to establish a direct communication with the main controller.
To exit Z-Wave range test, press the B-button briefly. Visual indicator will indicate the Z-Wave network’s range (range signalling modes described below). Wait for the visual indicator to glow violet. Wait for the visual indicator to glow white and short acoustic signal to sound. Testing may stress the network, so it is recommended to perform the test only in special cases.įollow the below instructions to test the main controller’s range: To make Z-Wave range test possible, the device must be added to the Z-Wave controller. For slopes greater than 20 degrees, it is recommended to install the sensor 50-100 cm from the highest part of the ceiling.īack To Top Z-Wave network Adding to the network When installing on sloped ceilings, the sensor should be installed in a horizontal position. The sensors must not be painted over or covered with furniture. If the corridor is L or U-shaped, installation in the middle of the corners is recommended. In standard corridors (up to 3 m) it is recommended to use smoke detectors every 15 m maximum. If the room has high furniture, fittings, or other high dividers, it is recommended to install more sensors. In standard rooms up to 60 m², one sensor is sufficient, except for L-shaped rooms or bigger rooms. It is recommended to install the sensor in every room except kitchens and bathrooms. If there is only one sensor on a floor, it is best to place it in the corridor leading to the bedrooms. There should be at least one sensor on each floor. Do not install the sensor in areas where the temperature exceeds the maximum temperature rating (0☌ – 55☌). Do not install the sensor in places with high water vapor condensation, e.g. above stoves, ovens, kettles, etc. The device can not be installed in places where the temperature exceeds operational values (0☌ – 55☌). Do not install the sensor in places prone to drafts. Keep at least 0.5m distance from light sources. Do not install the sensor in direct sunlight. Install the sensor at least 1.5m from air conditioners. Install the sensor in already decorated, painted rooms. Make sure the alarm sound can be easily audible in other rooms in the building.